Simple SCR/Triac Tester unit
Universal Rectifiers model # URK230504


Placeholder Picture

Step 1: Check Triac for short.

Connect one end of Jumper Lead #1 to Simple SCR/Triac Tester - Cathode Terminal and the other end to the MT1 Terminal of the Triac.

Connect one end of Jumper Lead #2 to Simple SCR/Triac Tester - Anode Terminal and the other end to the MT2 Terminal of the Triac.

At this point check the Test light on the Simple SCR/Triac Tester unit.

If the Test light is not glowing, then proceed to Step 2.

If the Test light IS GLOWING the Triac is short and should be replaced.

Step 2: Check Triac turn on.

Now connect one end of Jumper Lead #3 to the Simple SCR/Triac Tester - Gate Terminal and the other end, you will just touch the gate terminal of the Triac (the smaller tab) and then remove it.

At this point check the Test light on the Simple SCR/Triac Tester unit.

If the Test light is NOT glowing or just flashed as you touched the gate wire, you should replace the Triac.

If the Test light is glowing, then the Triac is good.


If you need some extra help just click a link below.

BackEmail: Mike SpeckEmail: Mike LlamasClick here to call now.